SCHY-5AG, 50AG, 100AG, 200AG, 400AG, 500AG AC current transducer

SCHY-5AG, 50AG, 100AG, 200AG, 400AG, 500AG AC current transducer

SCHY-5AG, 50AG, 100AG, 200AG, 400AG, 500AG AC current transducer

Input

5A-300A

Output

As per your request

Φ

35mm

Email: sales@zntar.com, zntarjason@gmail.com

More details


AC current transducer

CHY-5AG, 50AG, 100AG, 200AG, 400AG, 500AG

 

Sensor Module

CHY-5AG50AG100AG200AG400AG500AG

Description

The SENSOR Module CHY-AG is an AC current transducer to measure 5A…500A AC currents with a galvanic isolation between the primary and secondary circuits. The output of the transduceris a standard DC signal.

 

AC Current TransducerOutput 0…20mA:

Type

Nominal current

Output current

Accuracy

Supply voltage

Aperture

IN(A)

IM(mA)

X(%)

Vc(V)

mm

CHY-50AG/A0

50

0…20

±0.5%

15~24

φ35

CHY-100AG/A0

100

 

 

 

 

CHY-200AG/A0

200

 

 

 

 

CHY-400AG/A0

400

 

 

 

 

CHY-500AG/A0

500

 

 

 

 

 

AC Current TransducerOutput 4…20mA:

Type

Nominal current

Output current

Accuracy

Supply voltage

Aperture

IN(A)

IM(mA)

X(%)

Vc(V)

mm

CHY-50AG/A1

50

4…20

±0.5%

15~24

φ35

CHY-100AG/A1

100

 

 

 

 

CHY-200AG/A1

200

 

 

 

 

CHY-400AG/A1

400

 

 

 

 

CHY-500AG/A1

500

 

 

 

 

 

AC Current TransducerOutput 0…5V:

Type

Nominal current

Output voltage

Accuracy

Supply voltage

Aperture

IN(A)

VM(V)

X(%)

Vc(V)

mm

CHY-50AG/V0

50

0…5

±0.5%

15~24

φ35

CHY-100AG/V0

100

 

 

 

 

CHY-200AG/V0

200

 

 

 

 

CHY-400AG/V0

400

 

 

 

 

CHY-500AG/V0

500

 

 

 

 

 

AC Current TransducerOutput 1…5V:

Type

Nominal current

Output voltage

Accuracy

Supply voltage

Aperture

IN(A)

VM(V)

X(%)

Vc(V)

mm

CHY-50AG/V1

50

1…5

±0.5%

15~24

φ35

CHY-100AG/V1

100

 

 

 

 

CHY-200AG/V1

200

 

 

 

 

CHY-400AG/V1

400

 

 

 

 

CHY-500AG/V1

500

 

 

 

 

 

Specifications: 

Principle

Transducer

Input current

5A…500A(AC)

Output

One of A0=0~20mA、A1=4~20mA、V0=0~5V、V1=1~5V(DC)

Frequency

50Hz(400Hz)

Accuracy

±0.5%

Response time

<0.35S

Linearity

<0.5%

Supply voltage

+15V…24V(±5%)

Consumption

30mA+IM(Output current)

Isolation voltage

Between primary and secondary circuit: 6KV RMS/50Hz/1min.

Operating temp.

-25℃ …+85℃

Applications

The sensors are used in the industry field of power supplies, welding machines, converters,

 

industry auto-control, motor drives, electronic power system, railways, rectifiers systems etc.

 

Dimensions(mm) & Connection:    

 AC current transducer CHY-5AG